Ezyhot RV

Specifications

Technical data for the Ezyhot RV Tankless Hot Water System. 65,000 BTU dual stage burner for efficient hot water in all climates, including high altitudes.

65,000 BTU dual stage at a glance

  • 65,000BTU dual stage burner
  • All climatesEfficient dual stage heat
  • High altitudeWorking range to 1,372 m
  • 10 L/minHot water capacity

Technical data

Full specifications

Performance figures from the Ezyhot RV user manual, including 65,000 BTU dual stage input and a working altitude of 0 to 1,372 m. Installation must be completed by a qualified technician.

Model G10FWHCAU
Max gas input 65,000 BTU (68.4 MJ/h)
Min gas input 17.7 MJ/h
Fuel Propane (LP Gas)
Manifold pressure 0.25 kPa to 1.4 kPa
Maximum inlet gas pressure 3.50 kPa
Minimum inlet gas pressure 2.50 kPa
Electrical rating / voltage DC 12V, less than 5A
Maximum working water pressure 0.8 MPa
Minimum working water pressure 0.1 MPa
Setting temperature range 35°C to 50°C (95°F to 124°F)
Water heating capacity 10 L/min (Δt = 25K)
Working altitude 0 to 1,372 m (0 to 4,500 ft)
Intended use Recreational vehicles (RVs) only
  • Safety systems

    Flame monitoring, antifreeze, reverse polarity protection, voltage and over current shutdown, over temperature monitoring, blower monitoring, fluctuation eliminator, and pressure relief valve.

  • Not for DIY install

    Installation and service must be performed by a qualified installer, service agency, or gas supplier with a certificate of compliance.

  • RV use only

    Designed exclusively for recreational vehicles. Not suitable for marine applications, pool heating, or permanent dwelling installs outside intended RV use.